Product Details:
Minimum Order Quantity | 100 Meter |
Conductor | 12 AWG to 24 AWG (2.44mm to 0.51mm) as per ASTM E 230 - ANSI MC 96.1 |
Core Insulation | Flame Retardant PVC with nominal thickness of 0.40 mm |
Available No of Pair | 2, 4, 6, 8, 16, 20, 24, 36 and more |
Communication Wire | 22 AWG - 7 strands Tinned Copper wire Orange color PVC Insulated (4 Pair & larger) |
Pair Laying | Shielded Pairs with communication wire are laid suitably and binded with polyester tape |
Cable Shield | 0.05 mm Aluminum Mylar /polyester tape, 25% overlap |
Drain Wire | 22 AWG - 7 strands of Annealed Tinned Copper Wire |
Outer Sheath | Flame Retardant PVC |
Color Coding | Confirms to ANSI MC 96.1 (International Color Code Available) |
In an industrial environment of induced voltage and electrical noise, PVC Insulated twisted overall shielded thermocouple pairs is an ideal selection. Twisted pairs & aluminum Mylar shield provides protection against cross talk, static & magnetic noise in thermocouple circuits.
Applications:
Available Options:
Product Details:
Conductor | 12 AWG to 24 AWG (2.44mm to 0.51mm) as per ASTM E 230 - ANSI MC 96.1 |
Cable Shield | 0.05 mm Aluminum Mylar /polyester tape, 25% overlap |
Outer Sheath | 22 AWG - 7 strands of Annealed Tinned Copper Wire |
Color Coding | Confirms to ANSI MC 96.1 (International Color Code Available) |
Core Insulation | Flame Retardant PVC with nominal thickness of 0.40 mm |
Available No of Pair | 2, 4, 6, 8, 16, 20, 24, 36 and more |
Individual Pair Shield | 0.05mm Aluminum Mylar tape with 125% coverage |
Drain Wire | 22 AWG - 7 strands of Annealed Tinned Copper Wire. |
Communication Wire | 22 AWG - 7 strands Tinned Copper wire Orange color PVC Insulated (4 Pair & larger) |
Pair Laying | Shielded Pairs with communication wire are laid suitably and binded with polyester tape |
In an industrial environment with electrolytic processes and nearby large motors, generators, transformers, induction heating, relay controls, power lines or control wire induced voltage and electrical noise, PVC Insulated twisted individual & overall shielded thermocouple pairs is an ideal selection. Twisted pairs & aluminum Mylar shield provides protection against cross talk, static & magnetic noise in thermocouple circuits.
Applications:
Utilities & Industrial Plants
Construction of New plants
Petrochemicals & Oil Refineries
Testing Rig Set Up
Thermocouple Circuits
Features:
Temp. Range: 105 °C & Rated 300 V
Flame Retardant
Moisture, Chemical & Solvent Resistant
Excellent Die Electric Strength
100% shield contact for noise reduction
Available Options:
PVC / HR PVC / FRLS / LSOH / LSZH / HPER etc. Insulation & Outer Jacket as per clients specifications
Outside SS METAL OVERBRAID
Color Code as per IEC, ANSI, DIN, BS, NFC, JIS. Refer Table
Product Details:
Thermocouple Grade Wire | YES |
Core Insulation | Flame Retardant PVC with nominal thickness of 0.40mm |
Number of Pair | 2, 4, 6, 8, 16, 20, 24, 36 and more |
Communication Wire | 22 AWG 7 strands Tinned Copper wire Orange color PVC Insulated |
Cable Shield | 0.05 mm Aluminum Mylar /polyester tape, 25% overlap |
Drain Wire | 22 AWG - 7 strands of Annealed Tinned Copper Wire. |
Inner Sheath | Flame Retardant PVC |
Armored Thermocouple Extension Wires are used for underground applications as GI wire armoring gives strong mechanical protection. Twisted pairs & aluminum mylar shield provides protection against crosstalk, static & magnetic noise in thermocouple circuits.
Cable for Type of Thermocouple GRADE CALIBRATION: T, J, K, E, N, R, S, B
Application:
Product Details:
Conductor | 12 AWG to 24 AWG (2.44mm to 0.51mm) as per ASTM E 230 - ANSI MC 96.1 |
Cable Shield | 0.05 mm Aluminum Mylar /polyester tape, 25% overlap |
Drain Wire | 22 AWG - 7 strands of Annealed Tinned Copper Wire |
Inner Sheath | Flame Retardant PVC |
Armoring | GI Round Wire or strip with min. 80% coverage |
Outer Sheath | Flame Retardant PVC |
Color Coding | Confirms to ANSI MC 96.1 (International Color Code Available) |
Core Insulation | Flame Retardant PVC with nominal thickness of 0.40 mm |
Available No of Pair | 2, 4, 6, 8, 16, 20, 24, 36 and more |
Communication Wire | 22 AWG - 7 strands Tinned Copper wire Orange color PVC Insulated (4 Pair & larger) |
Pair Laying | Shielded Pairs with communication wire are laid suitably and binded with polyester tape |
Features:
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor | Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1 |
Insulation | Polymide T apping with Braided or Lapped Fiber with High T emp. Varnish High Temp. Saturated |
Construction | Twisted / Flat |
Outer Sheath | Braided or Lapped Fiber with Silicon Varnish, High Temp. Saturated |
Overall Braiding | Asbestos Yarn |
Operating Temp | 600 Degree C |
Limit of Error | According to ASTM E230 / 77 / IEC 584 |
Color Code | According to ANSI MC 96.1 |
Available Options:
Product Details:
Minimum Order Quantity | 100 Meter |
Communication Wire | 22 AWG - 7 strands Tinned Copper wire Orange color PVC Insulated (4 Pair & larger) |
Core Insulation | Flame Retardant PVC with nominal thickness of 0.40 mm |
Drain Wire | 22 AWG - 7 strands of Annealed Tinned Copper Wire |
Inner Sheath | Flame Retardant PVC |
Outer Sheath | Flame Retardant PVC |
Pair Laying | Shielded Pairs with communication wire are laid suitably and binded with polyester tape |
Armoring | GI Round Wire or strip with min. 80% coverage |
Cable Shield | 0.05 mm Aluminum Mylar /polyester tape,25% overlap |
Conductor | 12 AWG to 24 AWG (2.44mm to 0.51mm) as per ASTM E 230 - ANSI MC 96.1 |
Color Coding | Confirms to ANSI MC 96.1 (International Color Code Available) |
Available No of Pair | 2,4,6,8,16,20,24,36 and more |
Applications:
Utilities & Industrial Plant
Construction of New plant
Petrochemicals & Oil Refinerie
Testing Rig Set Up
Thermocouple Circuits
Features:
Temp. Range: 105 °C & Rated 300 V
Flame Retardant
Moisture, Chemical & Solvent Resistant
Excellent Die Electric Strength
100% shield contact for noise reduction
Armoring supports against strong mechanical abuse
Excellent Longitudinal strength
Available Options:
PVC / HR PVC / FRLS / LSOH / LSZH / HPER etc. Insulation & Outer Jacket as per clients specification
Outside SS METAL OVERBRAID
Color Code as per IEC, ANSI, DIN, BS, NFC, JIS. Refer Table
Product Details:
Minimum Order Quantity | 100 Meter |
Brand | TECHNIVA |
Temperature (deg. Celsius) | 450 |
Power/Voltage | 250 v |
Length | 100 |
Accuracy (%) | AS PER ANSI |
Number Of Core | 2 |
Conductor Type | THERMOCOUPLE GRADE |
Range | 0 - 1200 DEG SIGNAL |
Production Capacity | 1000 METERS / DAY |
Model Number | 20558 |
Color | AS PER ANSI |
Conductor | - | Solid, Multistrade Thermocouple Grade Material as per ASTM E230 & ANSI MC 96.1 |
Insulation | - | PTFE Temperature Saturated |
Construction | - | Parallel conductors |
Outer Jacket | - | Fiber glass Insulated |
Braiding | - | Stainless Steel Braiding |
Operating Temperature | - | 450 C |
Limits of Error | - | According to ANSI MC 96.1 / IEC - 584 |
Colour Code | - | According to ANSI MC 96.1 / IEC - 584 |
Product Details:
Minimum Order Quantity | 100 Roll |
Length | 100 METER |
Brand | TECHNIVA |
Conductor Type | COMPENSATING |
Packing Type | BUNDLE |
Size | 7/36 SWG |
Color | ANSI |
Power Source | NA |
Accuracy (%) | CLASS 1 |
Number Of Core | 2 CORE |
Range | 0-1350 DEG SIGNAL |
Production Capacity | 5000 METERS / MONTH |
Model Number | TVA-TC-NC-001 |
Outer Sheath | TVA-PVC |
Temperature (deg. Celsius) | 105 DEG |
Cable Type | Flat pair construction |
Core / Strands | Stranded conductors available, 7/0.2mm |
Insulation Material | PVC Insulated |
Max. Temperature | +105°C |
Min. Temperature | -10°C |
Standards Met | Colour code (cores & jacket) to IEC-584-3 |
Thermocouple Type | N |
Tolerance | Class 2 |
Additional Information: