Product Details:
Material | Fiberglass |
Color | BS Colour Code |
Brand | TECHNIVA |
Size | 24 AWG - 7/36 SWG |
Usage/Application | Manufacturing of THERMOCOUPLE SENSORS & EXTN FROM THERMOCOUPLES TO SENSORS |
Armored | YES |
Cable Conductor | "J" - FE / CONSTANTAN |
Cable Size | Overall Diameter 4.00 mm NOMINAL |
Fire Resistant | YES |
Flame Retardant | YES |
Flexible Wires | YES |
Is It Armoured | YES |
Packaging Type | BUNDLES |
Temperature | 200 DEG C |
Weight | 20 KG / KM |
Power/Voltage | 250 V |
Cable Construction | TC-JX-FI/FJ/SsA-24M(7/36) |
TECHNIVA Series | STANDARD |
Calibration Temperature | 0 - 750 deg C |
Accuracy | +/- 1.00 deg C - 2.20 deg C |
TECHNIVA ORDERING CODE.............: TVA10001
TECHNIVA CONSTRUCTION CODE......: TC-JX-FI/FJ/SsA-24M(7/36)
Standard Parameters
Ordering Code : TC-JX-FI/FJ/SsA-24M(7/36)
TC.........: THERMOCOUPLE CABLE
JX..........: “J” – FE / CONSTANT Extension Grade
FI..........: Glass Fibre Insulated Braided, Varnished & Colour coded
FJ..........: Glass Fibre Jacketed Braided, Varnished & Colour coded
SsA........: Stainless Steel Wire Armoured Braided TVA-SS304L
24M.......: AWG MULTI STRAND Construction equivalent
7/36......: SWG MULTI STRAND Construction reference
*Colour code options ANSI / IEC / JIS / DIN on request
** Continuous Length 200 / 500 / 1000 meters on request
Additional Information:
Product Details:
Conductor Type | "J" Type Fe / Constantan |
Size | 24 AWG MULTISTRAND = 1/24 SWG |
Material | GLASS FIBRE INSULATED BRAIDED |
Brand | TECHNIVA |
Thermocouple Type | J-Type |
Temperature | Calibration Temperature Range : 0 - 760 deg C |
Length | 100 meter standard continuous length |
Accuracy | +/- 1.00 - 2.20 deg C |
Number Of Core | 2 |
Usage/Application | Used for manufacturing THERMOCOUPLE SENSORS |
Production Capacity | 20,000 meters / month |
Model Name/Number | TVA10002 |
Operating Temp | 200 |
Outer Jacket | GLASS FIBRE BRAIDED JACKETED |
Referred Standards | IS 8784,ANSI 96.1 |
Outer Braiding | Stainless Steel Overbraid TVA-SS304L |
TECHNIVA Series | STANDARD |
ORDERING CODE.............: TVA10002
CONSTRUCTION CODE......: TC-JX-FI/FJ/SsA-24M(1/24)
Standard Parameters
(+) YELLOW / (-) BLUE – Overall BLACK Tracer
Ordering Code Reference : TVA10002
TECHNIVA : TC-JX-FI/FJ/SsA-24M(1/24)
1. Type Of Cable
a. TC.........: THERMOCOUPLE CABLE
2. Calibration & Grade of TC Cable
a. JX..........: “J” – FE / CONSTANT Extension Grade
3. Type of Insulation / style & identification of Cores
a. FI..........: Glass Fibre Insulated Braided, Varnished & Colour coded as per international BRITISH Standard
4. Type of Jacket / style & identification of Cores
a. FJ..........: Glass Fibre Jacketed Braided, Varnished & Colour coded
5. Type Overall Final Armouring / Style /& Grade
a. SsA........: Stainless Steel Wire Armoured Braided TVA-SS304L
6. Details of Size in “AWG” Equivalent Reference with strand indicator
a. 24M.......: AWG MULTI STRAND Reference equivalent
7. Details of Size in “SWG” Equivalent Conductor Construction with stranding
a. 7/36......: SWG MULTI STRAND Construction reference
*Colour code options ANSI / IEC / JIS / DIN on request
** Continuous Length 200 / 500 / 1000 meters on request
Additional Information: